K-numberK243959
Device namePowder Free Nitrile Examination Gloves (Violet, Black, Green), Tested for Use with Chemotherapy Drugs, Fentanyl Citrate and Select Other Drugs
ApplicantLingshi Hongruida Health Protection Technology Co., Ltd.
Product codeLZC
Device classClass I
Decision dateFeb 24, 2025
DecisionSubstantially Equivalent
Regulation880.6250
AI Summary extracted from FDA summary PDF · never regenerated
Intended use

Powder Free Nitrile Examination Gloves in violet, black, and green colors designed for medical examination use to prevent contamination between patient and examiner. The gloves have been tested for resistance to permeation by chemotherapy drugs (including Bleomycin, Cisplatin, Doxorubicin, and 31 others), Fentanyl Citrate, and select other drugs using ASTM D6978-05(2019) standard.

Technological characteristics

Nitrile material, ambidextrous, single-use, non-sterile, powder-free design in sizes XS through XXL with identical dimensional specifications (length, palm width, thickness) and mechanical properties (tensile strength ≥14 MPa, elongation 500% before aging, 400% after) as the predicate device. Key difference is color (violet, black, green vs. blue predicate) and inclusion of additional product codes (OPJ added to predicate's LZA, LZC, QDO).

Test standards cited

ASTM D6319-19 (nitrile glove specifications), ASTM D412-16(2021) (tensile testing), ASTM D5151-19 (hole detection), ASTM D6124-06(2022) (powder residue), ASTM D6978-05(2019) (chemotherapy drug permeation), ISO 10993-5:2009 (cytotoxicity), ISO 10993-10:2021 (skin sensitization), ISO 10993-11:2017 (acute systemic toxicity), ISO 10993-23:2021 (skin irritation).

Substantial equivalence argument

The subject device uses identical nitrile material, design, construction, and mechanical properties as the predicate device K221269. All non-clinical performance tests (physical dimensions, tensile strength, elongation, water leak, powder residue, biocompatibility) yielded same or better results than the predicate. Chemical permeation results for 33 chemotherapy drugs and 4 other drugs met or exceeded predicate performance (minimum breakthrough times ≥240 minutes for most compounds except Carmustine and Thiotepa, which carry explicit warnings). Color variation and additional product code do not raise safety or effectiveness concerns as evidenced by identical physical and biocompatibility test results.

Extracted by AI from the official FDA summary PDF →
Source

View the full FDA submission: accessdata.fda.gov

Researching this as a predicate?
Want a transparent AI-ranking score, AI-discovered related predicates, ongoing safety and warning-letter monitoring, full predicate chain lineage, and a drafted SE rationale — all saved to your own project? That's what an account adds.
Start free trial →

Everything you need for a 510(k) submission. Nothing you don't.

14-day free trial. No setup. Cancel anytime.

Start free trial →
Building an AI or ML-enabled device? Predicate search, PCCP tracking, and AI-specific FDA intelligence — built exclusively for AI/ML devices. Try AIFDA Intel →